Commit Graph
6 Commits
Author SHA1 Message Date
d3473f9ed4 fix(cli): forward Claude API error records with null service_tier (#1857) (#2087)
Claude Code writes failed API calls ("Prompt is too long", usage limits,
logged out) as synthetic assistant records whose usage carries
`service_tier: null`. The schema only accepted undefined, so the local
session scanner dropped every one and the web session just looked stalled.

- Accept null for the usage fields the Messages API types as nullable.
- Keep the top-level `error`/`isApiErrorMessage` on assistant records in
  local mode, and `error` in the SDK converter for remote mode.
- Render assistant records carrying `error` as the existing error event,
  so the all-zero synthetic usage no longer resets the context gauge.

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-26 10:00:23 +08:00
60a4971087 fix(cli): forward Claude Code 2.x subagent transcripts in local mode (#1904) (#2091)
Claude Code 2.x writes each subagent to <session>/subagents/agent-*.jsonl
instead of the main session log. The local session scanner only read the
main log, so subagent activity of local Claude sessions never reached the
hub and Agent/Task cards stayed empty.

Scan the subagents directory of every tracked session and stamp
parentToolUseId from the sibling agent-*.meta.json (toolUseId), so the
web tracer groups the transcript under its Agent card. Subagent files
already present at startup are marked seen, like the main log.

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-26 09:59:36 +08:00
Junmo KimandGitHub 95eee432d4 perf(claude): scan transcripts incrementally (#1081)
* perf(claude): scan transcripts incrementally

The claude session scanner re-read the entire transcript JSONL on every
scan, so the cost of each poll grew with the length of the conversation.
Track a byte offset per file instead and parse only the bytes appended
since the previous scan.

A trailing partial line — a write still in progress — is held back until
its newline arrives. A file that shrank resets the cursor to 0; the base
scanner's uuid dedup absorbs the re-sent events. A read that fails
returns no events and leaves the cursor where it was, so a transient
error is retried on the next scan rather than skipping content.

The codex scanner received this in #1031; this extends the same
improvement to the claude scanner. readSessionLog is exported for tests,
mirroring readTranscriptRange there.

* fix(claude): forward a complete final record with no trailing newline

The incremental reader consumed only through the last newline, so a final
JSONL record flushed without its terminating newline — at shutdown or on
import — was held back as if it were a partial write and never forwarded
until a later append supplied the newline. The previous whole-file reader
parsed such a record.

Consume a trailing segment when it already parses as a complete JSON value,
and keep holding back a genuinely partial line (which parses as incomplete).
2026-07-19 12:23:09 +08:00
lekoandGitHub bb04247127 Fix CLI tests on Windows paths (#643) 2026-05-19 07:53:28 +08:00
weishu bf72e0dc3b chore: remove unused test fixtures and disable dead test case 2025-12-21 19:16:24 +08:00
weishu b4654acb92 init 2025-12-16 15:03:50 +08:00